A TASK
Providing the hotel with drinking water with a capacity of 30 m3 / day from the mountain river of the village. Hotel "Guesthouse" with. Yablunytsya, "Bukovel"
WATER SOURCE
Well group
PROBLEMS
The water in the mountain river can be contaminated with untreated sewage discharged from hotels upstream. When precipitation falls, clay appears in large quantities in the water, see photo.
SOLUTION
Dosing of 3 types of reagents, manufacture of a flocculator, installation of a complex of tanks for clarification of water in the contact chamber, purification at 2 stages of filtration, removal of Cl, reverse osmosis for drinking water in a restaurant, water conservation with an Akvirs silver ionizer (own development, a patent for the invention has been received).